Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Dig Dis Sci ; 66(1): 238-246, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32128647

RESUMO

BACKGROUND AND AIMS: Data on comparative efficacy of various available endoscopic ultrasound-guided liver biopsy (EUS-LB) needles are limited. We sought to compare the performance of a novel Franseen-tip 22G fine-needle biopsy (FNB) device to that of 19G needle platforms for liver parenchyma. METHODS: Consecutive patients referred for EUS and suspected to have hepatic parenchymal disease underwent EUS-LB using different EUS needles and were included in this retrospective study. Two blinded expert liver pathologists independently reviewed and reported on: total number of tissue fragments, length of longest fragment, number of complete and incomplete portal tracts (CPT and IPT), and specimen adequacy. RESULTS: A 22G Franseen-tip needle (A) was used in 30 patients; 19G Tru-Cut needle (B) in 50 patients; 19G reverse beveled non-Tru-Cut needle (C) in 27 patients; and a 19G flexible non-Tru-Cut needle (D) in 28 patients. In the order of needles, A, B, C and D, > 10 tissue fragments were obtained in 100%, 6%, 82%, and 96% samples, the mean number of CPTs was 6.9; 3.0; 7.3; and 16.9, length of longest fragment was 3.8, 4. 7, 3.9, and 8.4 mm, and specimen adequacy was 66.7%, 46%, 82.1%, and 81.5%, respectively. A positive correlation was obtained between number of CPTs and length of longest fragment in samples accrued by 19G needles. CONCLUSION: EUS-LB specimens using 22G Franseen-tip needle appear highly fragmented, leading to inferior specimen adequacy compared to 19G non-Tru-Cut needles. We also report on using length of longest fragment as an additional criterion for specimen adequacy as it positively correlates with number of CPTs standard.


Assuntos
Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/normas , Hepatopatias/diagnóstico por imagem , Agulhas/normas , Adulto , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Feminino , Humanos , Biópsia Guiada por Imagem/métodos , Biópsia Guiada por Imagem/normas , Hepatopatias/patologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos
2.
Health Phys ; 109(5): 511-21, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26425910

RESUMO

The threat of radiation exposure from warfare or radiation accidents raises the need for appropriate animal models to study the acute and chronic effects of high dose rate radiation exposure. The goal of this study was to assess the late development of fibrosis in multiple organs (kidney, heart, and lung) in survivors of the C57BL/6 mouse model of the hematopoietic-acute radiation syndrome (H-ARS). Separate groups of mice for histological and functional studies were exposed to a single uniform total body dose between 8.53 and 8.72 Gy of gamma radiation from a Cs radiation source and studied 1-21 mo later. Blood urea nitrogen levels were elevated significantly in the irradiated mice at 9 and 21 mo (from ∼22 to 34 ± 3.8 and 69 ± 6.0 mg dL, p < 0.01 vs. non-irradiated controls) and correlated with glomerosclerosis (29 ± 1.8% vs. 64 ± 9.7% of total glomeruli, p < 0.01 vs. non-irradiated controls). Glomerular tubularization and hypertrophy and tubular atrophy were also observed at 21 mo post-total body irradiation (TBI). An increase in interstitial, perivascular, pericardial and peribronchial fibrosis/collagen deposition was observed from ∼9-21 mo post-TBI in kidney, heart, and lung of irradiated mice relative to age-matched controls. Echocardiography suggested decreased ventricular volumes with a compensatory increase in the left ventricular ejection fraction. The results indicate that significant delayed effects of acute radiation exposure occur in kidney, heart, and lung in survivors of the murine H-ARS TBI model, which mirrors pathology detected in larger species and humans at higher radiation doses focused on specific organs.


Assuntos
Síndrome Aguda da Radiação/etiologia , Síndrome Aguda da Radiação/fisiopatologia , Modelos Animais de Doenças , Insuficiência de Múltiplos Órgãos/etiologia , Insuficiência de Múltiplos Órgãos/fisiopatologia , Irradiação Corporal Total/efeitos adversos , Síndrome Aguda da Radiação/diagnóstico , Animais , Relação Dose-Resposta à Radiação , Feminino , Humanos , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Especificidade de Órgãos/efeitos da radiação , Doses de Radiação , Fatores de Tempo , Irradiação Corporal Total/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...